31
Installation and Connection
3.5.9 Optional
Speed Control
Wiring
7 1 8
PLC
Potentiometer
3K to 10K Ohm
Dual preset
speeds
PLC source
0 to 10VDC
Ri = 4K Ohm
+10V
REF
COM
+-
7 1 8
+10V
REF
COM
7 1 8
+10V
REF
COM
CP10 CP9
CP10 CP9
7 1 8
+10V
REF
COM
CP10
Single preset
speed
CP10 = max
frequency
CP9 = low
frequency
3.5.10 F4si to
F5Bi conversion
There are two differences between the F4si and F5Bi drives. First the
numbering of the pins has changed, these are shown below. Seconded is
that the internal voltage supply is 24 VDC and not 15VDC. If external
hardware is used verify the compenants compatiblity.
F4si
F5Bi
24 25 26
1 5 7 8 10 11 14 15 16 20 22
REF
ZERO SPEED
OUTPUT
COM
+10 VDC
QUICK
STOP
STOP INDEX
START
FOR/REV
0V
24 VDC
DRIVE
ENABLE
RLA
RLB
RLC
27 28 29
FLA
FLB
FLC
1 2 38 10 7 4 5 13 12 14 11 6
RLA
RLB
RLC
9
20 11
10
14 15
S1
Stop
Switch
Jog
Start
Pulse
S1
Jog
direction
S1
open = forward
closed = reverse
Index
direction
7
1 8
S1
Not used if index is
always forward
Start
Forward/Reverse
Stop Index
+24V
+10V
REF
COM
S1: AUTO/JOG Selector, 3PDT
shown in AUTO position
16
Drive Enable
Drive
Enable
open = no operation
closed = drive ready
see speed select
options
Quick Stop
Stop
Quick
3.5.11 Optional
Jog Wiring