Drive Mode
4.6 The "Drive Mode"
The Drive Mode is a operating mode of KEB COMBIVERT that permits the
manual starting of the drive through the keypad display unit. After applying
a signal to the control release terminal 16, the set value (speed ref.) and
rotation setting are effected exclusively over the keypad. In order to
activate the Drive Mode the corresponding password (500) must be
entered in CP.0. The display switches over as follows.
Direction of rotation
F=forward, r=reverse
Status
noP = "control release" deactivated
LS = neutral position
Set frequency can be changed
with the UP/DOWN keys while
holding the FUNC/SPEED key
4.6.1 Start / Stop
Drive
4.6.3 Speed
setting
4.6.2 Changing
the Direction
of Rotation
To exit the Drive Mode the inverter must be in status “stop” (Display noP
or LS). Press the FUNC and ENTER keys simultaneously for about 3
seconds to leave the Drive Mode. The CP-parameters appear in the
display.
4.6.4 Leaving
"Drive Mode"
Modulation blocked,
Drive in standby mode
Drive decreases to 0 Hz and
switches the modulation off
Drive accelerates up
to the adjusted set
value (speed ref.)
Drive operates with adjusted set
value (speed ref.)
Drive changes direction of rotation
The display changes when the
FUNC/SPEED key is pressed.
The set frequency is displayed.
+
for 3 seconds