Installation and Connection
3.5.7 Suggested
wiring
If the thermal protection won't be used a jumper between terminals
T1 & T2 need to be added.
24 25 261 5 7 8 10 11 14 15 16 20 22
REF
ZERO SPEED
OUTPUT
COM
+10 VDC
QUICK
STOP
STOP
INDEX
START
FOR/REV
0V
24 VDC
DRIVE
ENABLE
Run Speed Adjust
(3K to 10K)
OPEN = NO OPERATION
CLOSED = DRIVE READY
*Cycle INPUT 16 for Error
Reset
OPEN = FORWARD
CLOSED = REVERSE
MOMENTARY PULSE
STARTS INDEX
RLA
RLB
RLC
DRIVE FAULT
RELAY
OPEN = QUICK STOP
CLOSED = NORMAL
OPERATION
27 28 29
FLA
FLB
FLC
PROGRAMABLE
RELAY
*See Diagram 3.5.9 -
Optional Speed Control
Wiring
NOTE: Default is Zero
Speed Output on Pin 28,
FLB
STOP SIGNAL - SUPPLIED WITH
A MECHANICAL SWITCH (NO)