VIII. APPLICATION WIRING DIAGRAMS (Reversible Models)
P/N 92A61633020000 (120 VAC) – P/N 92A61633040000 (240 V
AC).
Reversing models carry out the same functions as the unidirectional models except they can
be made to index in both the forward and reverse direction. A special circuit APRM® pro-
vides a lockout feature that prevents catastrophic damage to the drive if a “Reverse” com-
mand is given during “Forward” operation (and vice versa).
The reversing drives contain two
additional positions on the terminal block: “Run Rev” and “Jog Rev.” The stop logic com-
mand is made with a normally closed (NC) contact.
Note: The sense of the stop logic can be changed from normally closed (NC) to nor-
mally open (NO) by placing jumper JS in the “NO” position.
The wiring diagrams on page 16 illustrate typical logic circuits. Many other configurations are
possible. Consult factory if help is needed.
IX. OPERATION
W
ARNING! Read Safety W
arning on page 2 before attempting to operate the
control or severe injury or death can result. Failure to follow the Safety
W
arning Instructions may result in electric shock, fire or explosion.
ROTATION
OF CAM
C
ONTACT IS OPENING
L
S1
L
S1
C
ONTACT CLOSES
1) CLOSE START BUTTON TO INITIATE
C
YCLE (MOMENTARY CLOSURE)
2) CAM ROTATES, LS1 CONTACT CLOSES
CLOSED
CONTACT REMAINS
LS1
LS1
C
ONTACT OPENS
1) CAM CONTINUES TO ROTATE THROUGH
CYCLE, LS1 REMAINS CLOSED
4)
CAM ROT
A
TES UNTIL LOBE UNTIL LS1 CONTACT,
DRIVE BRAKES
T
O
A
STOP
. CLOSE MOMENTARY
START BUTTON TO INITIATE NEW CYCLE.
FIGURE 16 – SEQUENCE OF CYCLE ON DEMAND OPERATION
!